Canon

PART NO: RM1-4349-040

Check Stock

£204.50 (ex. VAT)

Add to cart

Overview

Low priced Canon Fuser Unit RM1-4349, RM1-4349-030, RM1-4349-040, RC1-7606 compatible with

Canon iR C1021i, C1021iF Printer/Copier/Scan/Fax fuser
Canon i-SENSYS LBP-5300 Colour Laser Printer fuser          
Canon i-SENSYS LBP-5360 Colour Laser Printer  fuser
Canon i-SENSYS MF8450 Colour Laser Multifunction fuser
Canon i-SENSYS MF9130 Colour Laser Multifunction fuser
Canon i-SENSYS MF9170 Colour Laser Multifunction fuser

This fuser often has a sticker RC1-7606 or RCI-7606 to indicate 220/240v UK usage 

Please note that if the Canon badged RM1-4349, RMI-4349 is unavailable we may supply the identical Canon fuser with a Hewlett Packard (HP) badge

Common Canon Error Codes :

E000

The fixing temperature does not go up after turning ON the power

due to a fault in the thermistor or the heater, etc., (e.g. It does not

reach 70??C degrees within 2 min.)

E001 

The fixing temperature abnormally goes up due to a fault in the

thermistor or SSR, etc.

E002

The fixing temperature does not reach a specific temperature due

to a fault in the thermistor or the heater, etc.

e.g) The fixing temperature does not go up to 190??C degrees

within 5 min after reaching 70??C degrees.

E003

The fixing temperature drops abnormally after wait time is up due

to a fault in the thermistor, the heater, etc. (e.g. After wait time is

up, the fixing temperature drops to 70??C degrees).

E004 

A short circuit in the fixing heater drive circuit (SSR, etc) is

detected.

E005 The fixing web is wound up completely.

E006 The fixing drawer connector is not connected as the front door is closed.

E007 The fixing film is off to the side.

E008

A specific number of copies are made after the machine detects

that fixing oil is out.

E009 The rated voltages of the power supply and the fixing unit do not

E010 Clock pulses fail to be generated or the PLL lock fails to be

released due to a fault in the main motor unit

E011 Excess current flows to the motor control circuit because the main

E012

Clock pulses fail to be generated or the PLL lock is released due to 

a fault in the drum motor, etc.

 

This fuser also fits the following HP Colour LaserJet printers

HP 2700, HP 3000, HP3600, HP 3800, HP CP3505